Specifications | Voltage DC | Maximum Voltage: | 1000 V | Accuracy: | ±(0.09%+2) | Maximum Resolution: | 0.001V |
| Voltage AC | Maximum Voltage: | 1000 V | Accuracy: | ±(2%+3) | AC Bandwidth: | 5kHz* | | *with low pass filter; 3db @ 800 Hz | Maximum Resolution: | 0.1 mV |
| Current DC | Maximum Amps: | 400mA | Amps Accuracy: | ±(0.2%+2) | Maximum Resolution: | 0.01 mA |
| Current AC | Maximum Amps: | 400mA | Amps Accuracy: | ±(1.5%+2)* | | * 1kHz bandwidth | Maximum Resolution: | 0.01 mA |
| Resistance | Maximum Resistance: | 50 MΩ | Accuracy: | ±(0.9%+2) | Maximum Resolution: | 0.1Ω |
| Capacitance(1587 only) | Maximum Capacitance: | 9,999 µF | Accuracy: | ±(1.2%+2) | Maximum Resolution: | 1 nF |
| Frequency (1587 only) | Maximum Frequency: | 100 kHz | Accuracy: | ±(0.1%+1) | Maximum Resolution: | 0.01 Hz |
| Temperature Measurement (1587 only) | | -40.0 °C to 537 °C | | -40.0 °F to 998 °F | | excluding probe |
| Diode Test (1587 only) | Range: | 6 V | Resolution: | 1 mV | Accuracy: | ±(2 % + 1) |
|
Insulation Test | Minimum Test Current @ 1kΩ/V: | | Test Voltages: | 50, 100, 250, 500, 1000 V |
|
| Maximum Resistance per Test Voltage: | 50V: | | 100V: | | 250V: | | 500V: | | 1000V: | 2 GΩ |
| Maximum Resolution per Test Voltage: | 50V: | 0.01 MΩ | 100V: | 0.01 MΩ | 250V: | 0.1 MΩ | 500V: | 0.1 MΩ | 1000V: | 0.1 MΩ |
| Accuracy per Test Voltage: | 50V: | ±(3 % + 5) | 100V: | ±(3 % + 5) | 250V: | ±(1.5 % + 5) | 500V: | ±(1.5 % + 5) | 1000V: | ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ |
|
Environmental Specifications | Operating temperature | | Storage temperature | | Humidity (Without Condensation) | | 0% - 95% (10 °C – 30 °C) | | 0% - 75% (30 °C – 40 °C) | | 0% - 40% (40 °C – 55 °C) |
| Operating Altitude | |
Safety Specifications | Overvoltage category | | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
| Agency Approvals | | 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
|
Mechanical & General Specifications | Size | | 203 x 100 x 50 mm (with holster) |
| Weight | | Warranty | | Battery life Alkaline | Meter use: | 1000 hours | Insulation test use: | Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
| IP Rating | |
|
|
|