Category 6 MT-Series Unscreened Keystone Jack, T568A/B Wiring, Orange
- TRANSMISSION PERFORMANCE
- ANSI/TIA-568-C.2: meets or exceeds category 6 (1-250 MHz) component specifications
- TRANSMISSION MEDIA
- Unscreened twisted pair (U/UTP)
- JACK TYPE
- 8p8c (8-position, 8-contact) “RJ45” style
- WIRING SCHEME
- ANSI/TIA-568-C.2: T568A & T568B
- ISO/IEC 11801 2nd Ed.: 8-position pin/pair assignment (1-2/3-6/4-5/7-8)
- WIRE GAUGE
- 22 to 24 AWG (0.644 to 0.511 mm)
- ELECTRICAL
- Insulation Resistance: Min 500 MOhm @ 100 Vdc
- Dielectric Withstanding Voltage: 1,000 Vdc/ac peak contact-to-contact @ 60 Hz for 1 min
- Spring Wire Contact Resistance: Max 20 mOhm
- IDC Contact Resistance: Max 2.5 mOhm
- Current Rating: Refer to downloadable spec sheet.
- CONSTRUCTION
- Housing: High impact thermoplastic, UL94V-0 fire retardant
- Jack Spring Wire: Phosphor bronze alloy plated with 50 μin of gold over 70 to 100 μin of nickel
- IDC: 110 type, phosphor bronze alloy with 100 μin 100% tin alloy
- MECHANICAL
- Total Contact Force: Min 800 g for 8 wire leads
- Retention: 50 N (11 lbf) for 60 ± 5 s
- Mating Cycle Life: Min 750 cycles
- FOOTPRINT
- Standard keystone footprint
- MOUNTING DIMENSIONS:
- 1.18” D x 0.67” W x 0.76” H (30.0 mm x 16.9 mm x 19.3 mm)
- ENVIRONMENTAL CONDITIONS
- Operating Temperature: 14 °F to 140 °F (-10 °C to 60 °C)
- Storage Temperature: -40 °F to 158 °F (-40 °C to 70 °C)
- Operating RH: 93% Max (non-condensing)
- COMPLIANCE
- ANSI/TIA-568-C.2, IEEE 802.3 ab, IEEE 802.3 af/at/bt, IEC 60512-99-002, FCC Part 68 Subpart F, UL 94V-0
- APPLICATIONS
- X.21, V.11, S0, ISDN, CSMA/CD 10BASE-T, 100BASE-TX, 100BASE-T4, 100BASE-T2, 1000BASE-T, 10GBASE-T, TR 4/16/100, 100BASE-VG, ATM LAN 25/51/155, TP-PMD
- WARRANTY
- 5-year Limited Component
- 25-year Signamax Cabling System
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- The Signamax Category 6 MT-Series Unscreened Keystone Jacks have been designed to meet the need for today’s high-bandwidth applications. These connectors are slim in profile for the highest density applications and have the ability to mount either color-coded icons for service identification or dust covers to protect unused jacks from dust and other contaminants.
- The contact design provides enhanced plug-to-jack connection integrity, protects against damage caused by insertion of 4- or 6-position plugs. Special design features allow these jacks to be terminated with a standard 110 single-position tool or with the Signamax four-pair tool, and are rated for a minimum of 750 plug insertions providing for the highest level of system reliability.
|
|
|
|
|
|
|